Then I install steam, and the game, and now it needs to be updated in order to play in "offline mode" I like steam And now I get a steam error "The steam servers are currently too busy to handle your request. Please try again in a few minutes. This is great!!!! You must log in or sign up to reply here. Show Ignored Content. Similar Threads - bypass steam install. Steam Winter Sale Dec. Replies: 5 Views: Replies: 12 Views: 1, Kevin Nov 28, The bypass valve must have a lower flow coefficient Cv than the PRV.
When using the same diameter bypass valve as the PRV, the safety valve will have to be sized for the bypass valve, which always will have a higher Cv. Sizing the safety valve for the bypass valve will usually require the safety valve to be extremely large in size and capacity. Safety valves are an important consideration in a steam PRV station. But they may not be required in every case. If any steam component or the steam line downstream of the steam PRV is not rated for the maximum inlet steam pressure to the PRV station, then a safety valve must be installed to protect the system.
The safety valve needs to be sized for the maximum steam flow with the highest steam pressure that could be provided to the PRV. In addition, to ensure the proper safety valve size, perform calculations with the largest Cv trim available for the PRV.
When installing a safety valve, be sure the discharge is piped to a location where it will not pose a safety risk for plant personnel. For example, when the steam flow varies greatly and one valve does not have the required turndown capabilities, an additional valve—or valves—will be required to achieve the desired outlet pressure. In systems with more than one PRV, the safety valve must be sized based on all valves failed in the open position and have the largest trim available from the manufacturer.
Note that the piping from the PRV to the downstream isolation valve should be designed and installed to meet the highest steam pressure at the inlet to the PRV.
The downstream isolation valve is located before the safety valve that protects the system. Therefore, if the isolation valve is closed and the PRV opens, the piping could experience the inlet steam pressure.
It is always good practice to install pressure gauges before and after the steam PRV as diagnostic tools. Be sure to include a siphon pipe and isolation valve for maintenance purposes. Every PRV station requires a SOP to ensure that plant personnel are starting, operating, and shutting down the valve station correctly and safety.
Valve manufacturers should provide a SOP as part of the documentation with the equipment. By paying careful attention to proper system design, component selection, and installation practices, you can prolong the life of components in your steam PRV station. Be sure to match the PRV to the application, minimize velocities, include drip pockets and strainers, and position components properly.
A dam, located a few hundred feet upstream of the project location, eliminated the possibility of allowing water to back up if stream flow would exceed pumping capabilities.
This meant that the bypass would require enough pumping power to handle the complete flow spectrum of the stream. With a successful history of similar bypass operations, E-Pump delivered a cost-effective and fail-safe stream bypass system designed to deliver one and a half times the maximum flow condition of the stream on demand.
The array of stand-by pumps provided the construction company versatility and the ability to handle variable flow ranges without risk of over-running an individual pump. Showing 1 - 15 of 38 comments. Zekiran View Profile View Posts. Are you attempting to install it on a computer that is not yours? Because if so: don't. Originally posted by Zekiran :. Well, there sort of is a way. But i dearly hope your admin is cool with it because if he isnt, you may get into trouble.